• Selectable filtering
  • For use with LVDT transducers
  • Aluminum housing sealed to IP65

DCM 480 Signal Conditioner

Unit of Measure

Specifications

Channels

N/A 1

Temp. Range

N/A 32 to 185 °F

Construction/Material

N/A Aluminum Housing-IP 65

Power Required

N/A 12 to 36 Vdc Universal Polarity

Transducer- Excitation

N/A 0.5V, 5mA rms 5kHz Sinusoidal Vdc

Transducer- Inputs Accepted

N/A 30 mv to 4 V rms

Amplifier- Accuracy

N/A ± 0.05 % F.S.

Analog Amplifier-Output

N/A 2-Wire, 4-20 mA

Amplifier-Bandwidth

N/A 250Hz. with Filter 25Hz (Flat)

Dim. D

N/A 2.2 Inch

Dim. L

N/A 4.92 Inch

Dim. W

N/A 3.15 Inch
Accessory Items1 N/A AC/SOT, Assembly and Calibration of Transducer to Instrumentation ($185.00)
  • 1 Multi-Channel instruments will require an additional calibration fee.